SDG 7 - Affordable and Clean Energy

Many buildings and rooms at the University of Waterloo are not performing at the level they were designed to operate at. Recommissioning involves identifying and addressing systems that are not operating at optimal levels and considering how these systems interact to affect overall performance. Which rooms on campus require the greatest improvement and how can we determine this?

Information Technology (IT) uses a lot of electricity, and often the computers, servers and supportive technologies are not optimized for energy efficiency. What strategies can the University of Waterloo use to reduce electricity use in computer labs and server rooms on peak demand days and throughout the year?

The use of e-bikes is a great mode of alternative transportation. The University of Waterloo has 18 EV chargers. However, parking in these spots is limited to 4 hours. Additionally, there are no dedicated e-bike parking or charging stations. To what extent should the university adopt and support electric alternatives and their required infrastructure?

There are 4 air handling units in the Quantum Nano Centre (QNC) that have a poor design which results in excessive stratification of inlet air. Past attempts to improve this situation have failed. How can these units be improved to more effectively mix incoming and outlet air?

Too often, important decisions are made based almost entirely on very narrow economic factors: upfront costs, operational costs, payback periods, etc. and do not take into consideration other implications like health. What communication tools can the University of Waterloo use to highlight the health-based benefits of sustainable practices on campus?

There is a growing interest in wastewater heat recovery as an innovative approach to decarbonizing buildings.Can this approach be implemented on campus to reduce the energy and fuel needed to operate the district heating system? Can the system be reversed to provide cooling in the summer months?

Natural gas is the main resource used for heating on campus. The steam-based district heating system operates year-round and supplies steam for much of the university's heating needs. Can electrified alternatives be used in the summer months to reduce annual gas use?

Food services currently uses natural gas for much of its cooking. With natural gas being the single largest source of energy emissions, is there a way to transition to electrified alternatives?

Many of the University of Waterloo's campus buildings were built at a time when insulation, air sealing, and thermal bridging were not major concerns. Consequently, these buildings are not optimal for saving energy and are a large source of greenhouse gas emissions. How can we improve these buildings by prioritizing high-performance building envelopes?