Name: Farhana Priana
Date: Dec 9, 2022
Time: 3:00pm
Location: Teams
Supervisors: Sheshakamal, Jayaram
Title: Thermal Aging Time-temperature Effects on Low Voltage EPR/XLPE Insulated Cables
Abstract: Low-voltage (LV) insulated cables are widely used in nuclear power plant environments in critical applications such as power transmission, control of equipment and instrumentation, and signal and data communication. Since the majority of nuclear power plants are nearing reaching their end-of-life, extending their operating life by up to 40 years is critical. As a result, assessing the health of LV cables has become a critical issue, as this is typically accomplished through destructive techniques.
Most cables are made with polymer insulation and jacket materials, which can become brittle, crack, or degrade over time due to exposure to harsh environmental conditions such as high temperatures, moisture, and radiation. Degradation of the properties of these materials, particularly the insulation, can result in a significant decrease in the overall health and performance of the cable, eventually leading to failure. Aging assessments are performed on cable polymers exposed to harsh conditions in service to identify and quantify the severity of degradation and determine when they will reach their end of life.
Cross-linked polyethylene (XLPE) and ethylene propylene rubber (EPR) insulated cables are among the most commonly used in the industry, and their use is continuing to increase. A variety of cable samples are thermally aged at 130 °C for different periods of time in this paper. These samples are subjected to frequency-domain dielectric spectroscopy (FDS) and polarization/depolarization current (PDC) measurements. The dielectric response characteristics of FDS and PDC are examined, and a variety of diagnostic ”metrics” derived from variable frequency dielectric response and polarization and depolarization current data have been trended as a function of aging time.
University of Waterloo
200 University Ave W, Waterloo, ON
N2L 3G1
Phone: (519) 888-4567
Staff and Faculty Directory
Contact the Department of Electrical and Computer Engineering
The University of Waterloo acknowledges that much of our work takes place on the traditional territory of the Neutral, Anishinaabeg and Haudenosaunee peoples. Our main campus is situated on the Haldimand Tract, the land granted to the Six Nations that includes six miles on each side of the Grand River. Our active work toward reconciliation takes place across our campuses through research, learning, teaching, and community building, and is centralized within our Office of Indigenous Relations.